MODULAR POWER
SYSTEMS.

Our Engineers can produce & deploy at great speed, we can support a variety of industries that are disconnected, off-grid, or require emergency backup power; including...

ENERGY OUTPUT
5 – 100 MW
25 MW
5 MW100 MW
NUMBER OF UNITS REQUIRED
1 – 20
5 Units

99.999% with N+2 redundancy

SPEED TO POWER, MINIMIZED RISK & REDUCED ENVIRONMENTAL IMPACT

Natural Gas Generators

We work with Caterpillar. An established and proven company with 90+ years of reliability & Service with 24/7 global parts availability & Service network.

Commercial Off-The-Shelf Components (COTS)

Our Rectifiers, batteries & controls are built to industry standard with commercial guarantees. Multiple US suppliers for every component means no single source risk.

Patented Architecture, Not Proprietary Hardware

Our innovation is in how we integrate proven components, Load balancing software and fault tolerance ensures you get cutting-edge efficiency without bleeding-edge risk.

Cleaner For Your Community

Catalytic converters are optional inclusions for reducing up to 95% CO2, 98% NOx & 98% CO. Our patent pending output is DC native, meaning less potential heat exchange inside & this means less power & water usage.

Financial Model Simulator

What would an Ingenev power plant cost you over 20 years?

What these numbers include:
  • These calculations are an assumptive model based on EIA State data and are indicative only. Demand charges and incentives are not included.
  • Costs are in today's dollars, accumulated over 20 years with zero discounting. All stated costs are subject to change and are not to be construed as a full and final amounts.
  • Grid option: utility connection ($0.75M/MW), backup generator ($0.75M/MW), 60-minute N+1 UPS ($0.85M/MW), maintenance, UPS battery replacements, and grid energy.
  • Ingenev option: on-site natural gas plant with built-in battery (7.5 min), gas line, O&M from year 2, and natural gas fuel. Battery replacement is covered in the O&M fee.

Grid option vs Ingenev option figures are meant to demonstrate an approximate comparison for a new build or replacement. Every figure is an estimate with a ± 15% band.

WHAT STATE ARE YOU IN?
expand_more
Illinois EIA Industrial Baseline
POWER DEMAND20 MW
5 MW100 MW
ENERGY TARIFFS
DUTY & UPS RUNTIME
Built-in battery (no switchover)
Advanced Engineering AssumptionsClick to expand
ESTIMATED 20-YEAR FINANCIAL RESULTDynamic 20-year cost comparison based on selected state tariffs
About 40% Lower Cost
20-Year Estimated Total Savings Range
$166M to $225M
Estimated savings against grid connection + diesel generator + 60-min UPS.
Grid + Generator + UPS
Upfront Capital$52.0M
Annual Running Cost (Yr 3)$18.8M / yr
20-Year Total$416M to $563M
Ingenev Power Plant
Upfront Capital$42.7M
Annual Running Cost (Yr 3)$12.2M / yr
20-Year Total$250M to $339M
Approximate Ingenev System Price
Equipment, installation, commissioning, and project management
$32.0M to $43.4M
Gas Price Sensitivity: At power-sector gas ($4.34/Mcf): estimated saving $260M (53%). At industrial gas ($8.44/Mcf): estimated saving $131M (27%).
CUMULATIVE COST OVER 20 YEARS
Grid OptionIngenev
$0$150M$300M$450M$600MYr 0Yr 5Yr 10Yr 15Yr 20

Ingenev costs less from day one: its upfront cost is below the grid option's.

VALUE OF EARLIER POWERExample Values

Separate from the 20-year cost comparison. Ingenev delivers up to 70 MW in 18 months, subject to permitting.

Revenue Brought Forward
$30.0M
30 months of earlier operation before utility connection
mark_email_read

RECEIVE A MORE DETAILED FINANCIAL MODEL & REPORT BY CONTACTING ONE OF OUR ENGINEERING TEAM MEMBERS.

By adding your details below, you will receive a response from our team to further scope your model based on your inputs. To protect proprietary modeling methodology and your data requirements we will reach out and connect to discuss.

Instant PDF delivery to client inbox
MODULAR INFRASTRUCTURE

THE DC-INGEN.
CONTAINERIZED...

Use the slider to pull apart the 40 foot Caterpillar gas 3520 generator and the 20 foot Proprietary DC-INGEN.

Loading 3D Hardware Twin…
Daisy Chain Interconnect